Technical Specifications
| NO. | MODEL | S-PACK LB 24200 | S-PACK LB 48150 | S-PACK LB 48200 | Remark | |
| 1 | Item | General Parameter | ||||
| 2 | Combination method | 3.2V 100ah cell-8s2p or 3.2V 200ah cell-8s1p | 3.2V 150ah cell-16s1p | 3.2V 100ah cell-16s2p or 3.2V 200ah cell-16s1p | ||
| 3 | Rated Voltage | Typical | 200AH | 150AH | 200AH | Standard discharge after |
| Minimum | 195AH | 135AH | 195AH | Standard charge (package) | ||
| 4 | Factory Voltage | 26.0V~27.2V | 52.0V~54.4V | Mean Operation Voltage | ||
| 5 | Voltage at the end of discharge | 21.2V | 41.6V | Discharge Cut-off Voltage | ||
| 6 | Charging Voltage | 28.8V | 57.6V | |||
| 7 | Internal Impedance | ≤10M | ≤20M | ≤13M | Internal resistance measured at AC 1KHZ after 50% charge. The measure must use the new batteries that within one week after shipment and cycles less than 5 times | |
| 8 | Standard Charge | Constant Current:100A | Charge time:Approx 1h | |||
| Constant Voltage: See No.5 cut-off 0.02CA | ||||||
| Limiting Current | 10A | |||||
| 9 | Standard Discharge | Constant Current:100A End voltage :See No.4 | ||||
| 10 | Max Continuous Charge Current | 100A | T≥10℃ | |||
| 11 | Max Continuous Discharge Current | 100A | T≥10℃ | |||
| 12 | Openration Temperature Range | Charge: 0℃ ~45℃ | Bare Cell 60±25% R.H | |||
| Discharge: 120℃ ~55℃ | ||||||
| 13 | Storage Temperature Range | Less than 8 months : -10℃ ~35℃ | At the shipment state 60±25% R.H | |||
| Less than 3 months : -10℃ ~45℃ | ||||||
| Less than 7 days : -20℃ ~65℃ | ||||||
| 14 | Weight | 53±2kg | 62±2kg | 88±2kg | Include case | |
| 15 | Cycle life | ≥4000 times | ≥6000 times | 90% DOD-0.2/0.5C Charge/Discharge 25℃ 90% DOD-0.2/0.5C 25℃ | ||
Features:
LongCycleLife: 4000 times, service more than 10 years.10years.
HighPower: Supports long-term charging and discharging of 1C.
Physical characteristics: small size, light weight, thin thickness.
Installation mode: wall-mounted, hanging on the wall together with inverter and control to form a harmonious environment
The left and right sides of the battery and the panel are equipped with handles for easy installation and handling.
Safety: Level 4 protection, cell protection, BMS protection, inverter protection, air switch protection, grounding protection.
Communication: The battery supports the communication protocol of 90% inverter manufacturers on the market.
Solar/Wind energy storage system
Community/Villa/Residential/Hospital/School/Gymnasium etc